Arpad wrote: >For example, if the bit time is 400e-12 (ps) and the UI value is >0.5 for a certain parameter, the EDA tool would have to pass >200e-12 to the DLL, and not 0.5. I disagree. Since the EDA tool also must pass the bit time to the model, the model has all the information it needs, in order to convert from units of UI to units of seconds. -db -----Original Message----- From: ibis-macro-bounce@xxxxxxxxxxxxx [mailto:ibis-macro-bounce@xxxxxxxxxxxxx] On Behalf Of Muranyi, Arpad Sent: Wednesday, April 18, 2012 3:09 PM To: IBIS-ATM Subject: [ibis-macro] A technical question on UI Hello everyone, An interesting question was raised in the Editorial Committee meeting this morning, and I got the AR to write an email on this reflector to solicit for some comments and feedback. The question is revolving around parameters which are expressed in terms of UI (unit interval). A statement was made in the Editorial Committee meeting this morning, that if a parameter is a {snip} Confidentiality Notice. This message may contain information that is confidential or otherwise protected from disclosure. If you are not the intended recipient, you are hereby notified that any use, disclosure, dissemination, distribution, or copying of this message, or any attachments, is strictly prohibited. If you have received this message in error, please advise the sender by reply e-mail, and delete the message and any attachments. Thank you. --------------------------------------------------------------------- IBIS Macro website : http://www.eda.org/pub/ibis/macromodel_wip/ IBIS Macro reflector: //www.freelists.org/list/ibis-macro To unsubscribe send an email: To: ibis-macro-request@xxxxxxxxxxxxx Subject: unsubscribe