[ibis-macro] AMI Corner, and IBIS C_Comp, one more time

  • From: "Walter Katz" <wkatz@xxxxxxxxxx>
  • To: "IBIS-ATM" <ibis-macro@xxxxxxxxxxxxx>
  • Date: Wed, 12 Oct 2011 11:28:51 -0400 (EDT)

All,

 

I think AMI format Corner is well understood, although one could change
the following lines:

 

| Note that in the context of Algorithmic Model for type 'Corner', <slow 

| value> and <fast value> align implicitly to slow and fast corners, and 

| <slow value> does not have to be less than <fast value>. For type
'Range' 

| and 'Increment', <min value>, <max value> does not imply slow and fast 

| corners.

 

To say,

 

Note that in the context of Algorithmic Model for format Corner, <typ
value> <slow value> and <fast value> shall be the values used when the
IBIS Analog Model that is being used to generate the Impulse Response of
the channel shall use the IBIS analog model that corresponds to the
derivation methods as described for typical, slow-weak and fast-strong
respectively in section 9 of IBIS.

 

For C_comp (where C_Comp_Used is the value used in the simulation):

.         If an IBIS model has just C_comp the User/EDA tool shall choose
a value of C_Comp_Used from the values of C_comp when simulating typical,
slow-weak, or fast-strong IV and VT data. Although it is common practice
(but not required) to use the min value of C_comp for fast-strong IV and
VT data and C_comp max for slow-weak IV and VT data.

.         If a model has C_comp and C_comp_corner, then the User/EDA tool
shall choose either a value of C_Comp_Used from the values of C_comp in
accordance with the previous paragraph, or use the typ, min, max value of
C_comp_corner when simulating typical, slow-weak, or fast-strong IV and VT
data respectively.

 

This defines a default method of defining C_Comp_Used when C_comp_corner
is not defined and when C_comp_corner is defined.  C_comp_corner is
defined the User can direct the EDA tool to use the values of
C_comp_corner that correspond to the derivation methods of the IV and VT
tables, or use the values of C_comp either correlated or independent of
the IV and VT tables used.

Walter

 

Walter Katz

wkatz@xxxxxxxxxx

Phone 303.449-2308

Mobile 720.333-1107

 