[ibis-macro] Re: Event triggered PWL sources question

  • From: "Muranyi, Arpad" <arpad.muranyi@xxxxxxxxx>
  • To: <ibis-macro@xxxxxxxxxxxxx>
  • Date: Fri, 28 Oct 2005 09:17:51 -0700

That's the way it is done now in the release
I sent to the group yesterday.

Thanks for confirming my feelings.

Arpad
============================================

-----Original Message-----
From: ibis-macro-bounce@xxxxxxxxxxxxx [mailto:ibis-macro-bounce@xxxxxxxxxxxxx] 
On Behalf Of Todd Westerhoff (twesterh)
Sent: Friday, October 28, 2005 9:14 AM
To: ibis-macro@xxxxxxxxxxxxx
Subject: [ibis-macro] Re: Event triggered PWL sources question

 
First option sounds right to me too.  If I'm reading this correctly, the
second option essentially says the PWL source triggers at simulation
time 0 no matter what.  I don't see why that should be, so I vote for
option 1.

Todd. 

Todd Westerhoff
High Speed Design Group Manager
Cisco Systems
1414 Massachusetts Ave - Boxboro, MA - 01719 email:twesterh@xxxxxxxxx
ph: 978-936-2149
============================================
 
"Always do right.
 This will gratify some people and astonish the rest."
 
- Mark Twain


-----Original Message-----
From: ibis-macro-bounce@xxxxxxxxxxxxx
[mailto:ibis-macro-bounce@xxxxxxxxxxxxx] On Behalf Of Mike LaBonte
(milabont)
Sent: Thursday, October 27, 2005 9:07 AM
To: ibis-macro@xxxxxxxxxxxxx
Subject: [ibis-macro] Re: Event triggered PWL sources question

Arpad,

The first option sounds right to me too.

Mike

-----Original Message-----
From: ibis-macro-bounce@xxxxxxxxxxxxx
[mailto:ibis-macro-bounce@xxxxxxxxxxxxx] On Behalf Of Muranyi, Arpad
Sent: Wednesday, October 26, 2005 3:49 PM
To: ibis-macro@xxxxxxxxxxxxx
Subject: [ibis-macro] Event triggered PWL sources question
Importance: High

Hello everyone,

I have a question on how the event triggered PWL sources should be
implemented.  Please comment ASAP, since I am in the middle of doing
them now and I need your answers right away.

The goal is to have a something vs. time table in the PWL source which
can be reset to t=0 any time an input signal crosses a certain
threshold.  So far so good.

Question:  What should be the behavior be before the first event occurs?
For example, if the PWL source contains a table that is a waveform
defined for 0 to 2 ns, and the first event occurs at t=5ns, should the
output be the first point of the table up to 5ns, and then start the
waveform, or should the waveform begin at t=0 run its course once, and
then start over at 5ns and at every subsequent event?

Our library does the second one currently, but I think the first
description is the better (or more
correct) one.

Please comment.

Thanks,

Arpad
====================================================

---------------------------------------------------------------------
IBIS Macro website:  http://www.sisoft.com/ibis-macro IBIS Macro
archives: //www.freelists.org/archives/ibis-macro
To unsubscribe send an email:
  To: ibis-macro-request@xxxxxxxxxxxxx
  Subject: unsubscribe
---------------------------------------------------------------------
IBIS Macro website:  http://www.sisoft.com/ibis-macro IBIS Macro
archives: //www.freelists.org/archives/ibis-macro
To unsubscribe send an email:
  To: ibis-macro-request@xxxxxxxxxxxxx
  Subject: unsubscribe
---------------------------------------------------------------------
IBIS Macro website:  http://www.sisoft.com/ibis-macro
IBIS Macro archives: //www.freelists.org/archives/ibis-macro
To unsubscribe send an email:
  To: ibis-macro-request@xxxxxxxxxxxxx
  Subject: unsubscribe

---------------------------------------------------------------------
IBIS Macro website:  http://www.sisoft.com/ibis-macro
IBIS Macro archives: //www.freelists.org/archives/ibis-macro
To unsubscribe send an email:
  To: ibis-macro-request@xxxxxxxxxxxxx
  Subject: unsubscribe

Other related posts: