[ibis-macro] Re: Handling termination in BIRD 144

  • From: "Walter Katz" <wkatz@xxxxxxxxxx>
  • To: <feras@xxxxxxxxxxx>, "'IBIS-ATM'" <ibis-macro@xxxxxxxxxxxxx>
  • Date: Mon, 05 Mar 2012 23:25:38 -0500 (EST)

Feras,

 

I think the whole approach of BIRD 144 is ill advised. I think that you
need an IC Vendor to come to an ATM meeting and explain the problem you
are trying to solve and why specifically BIRD 116 does not address the IC
Vendor's needs. I therefore think BIRD 144 should be tabled until such
time as you get an IC Vendor to defend it.

 

Walter

 

From: ibis-macro-bounce@xxxxxxxxxxxxx
[mailto:ibis-macro-bounce@xxxxxxxxxxxxx] On Behalf Of Feras Al-Hawari
Sent: Monday, March 05, 2012 4:54 PM
To: 'IBIS-ATM'
Subject: [ibis-macro] Handling termination in BIRD 144

 

Hello,

 

I have updated BIRD 144 to support terminating: 1) unused ports, and 2)
connected ports. The example below shows how. Figures and more details
will be provided in the latest version of the BIRD , which will be
uploaded very soon.

 

|-------------------------------------------------------------------

|** Example of True Differential [External Model] using Touchstone:

|-------------------------------------------------------------------

|

|

[Model] Ext_Linear_Diff_Output_Buff_Touchstone

Model_type Output_diff

Rref_diff = 100

|

| Other model subparameters are optional

|

|                 typ     min    max

[Voltage Range]   3.3     3.0    3.6

|

[Ramp]

dV/dt_r        1.57/0.36n   1.44/0.57n   1.73/0.28n

dV/dt_f        1.57/0.35n   1.46/0.44n   1.68/0.28n

|

[External Model]

** Language Touchstone

 

|

| Corner corner_name file_name        circuit_name 

Corner    Typ         diffout_typ.s4p  NA

Corner    Min         diffout_min.s4p  NA

Corner    Max         diffout_max.s4p  NA

|

|** Ports List of port names (in same order as in Touchstone)

|

| Based on the Ports order below:

|** my_drive_pos should be connected to port 1 of Touchstone

|** A_signal_pos should be connected to port 2 of Touchstone

|** my_drive_neg should be connected to port 3 of Touchstone

|** A_signal_neg should be connected to port 4 of Touchstone

|

Ports my_drive_pos A_signal_pos my_drive_neg A_signal_neg 

|***

|**** Port_termination    reserved_port      ts_port   resistor_value
voltage_value

**** Port_termination        A_puref            NA           1e6
0.0

**** Port_termination        A_pcref            NA           1e6
0.0

**** Port_termination        A_pdref            NA           1e6
0.0

**** Port_termination        A_gcref            NA           1e6
0.0

**** Port_termination        my_drive_pos       1            50
NA

**** Port_termination        my_drive_neg       3            50
NA

|

| D_to_A d_port        port1          port2     vlow vhigh trise tfall
corner_name 

D_to_A    D_drive_pos   my_drive_pos   A_pdref   0.0  3.3   0.5n  0.3n
Typ

D_to_A    D_drive_pos   my_drive_pos   A_pdref   0.0  3.0   0.6n  0.3n
Min

D_to_A    D_drive_pos   my_drive_pos   A_pdref   0.0  3.6   0.4n  0.3n
Max

D_to_A    D_drive_neg   my_drive_neg   A_pdref   0.0  3.3   0.5n  0.3n
Typ

D_to_A    D_drive_neg   my_drive_neg   A_pdref   0.0  3.0   0.6n  0.3n
Min

D_to_A    D_drive_neg   my_drive_neg   A_pdref   0.0  3.6   0.4n  0.3n
Max

|

[End External Model]

 

Best regards,

 

Feras Al-Hawari