Walter,
Would this be hierarchically immediately under [Model]? If so, would any of
the threshold input or buffer output load subparameters or keywords be eligible
to appear *under* [Standard]?
* MM
From: ibis-macro-bounce@xxxxxxxxxxxxx <ibis-macro-bounce@xxxxxxxxxxxxx> On
Behalf Of Walter Katz
Sent: Tuesday, July 24, 2018 11:51 AM
To: IBIS-ATM <ibis-macro@xxxxxxxxxxxxx>
Subject: [ibis-macro] New Keyword [Standard]
All,
I would like to propose a new [Model] keyword :
[Standard] <Standard Name> <Buss name>
Example:
[Standard] JESD79-4 DQ
Required No
Can a model have more than one [Standard] record?
It is up the EDA tool to use any information in the [Standard] its chooses.
Walter
Walter Katz
wkatz@xxxxxxxxxx<mailto:wkatz@xxxxxxxxxx>
Office 978.461-0449 x 133
Mobile 720.417-3762