[ibis-macro] Re: New draft for BIRD197

  • From: "Fangyi Rao" <dmarc-noreply@xxxxxxxxxxxxx> (Redacted sender "fangyi_rao" for DMARC)
  • To: "Arpad_Muranyi@xxxxxxxxxx" <Arpad_Muranyi@xxxxxxxxxx>, 'IBIS-ATM' <ibis-macro@xxxxxxxxxxxxx>
  • Date: Wed, 10 Apr 2019 16:33:22 +0000

Hi Arpad,

I have two questions regarding the following statement in the BIRD.

" The waveform output of the Rx AMI_GetWave shall be adjusted so that the EDA 
tool can add DC_Offset to get the voltage of the waveform at the slicer (aka 
latch, decision point) of the single ended port."

Q1. If the waveform at the slicer is centered at 0V, then the waveform output 
of the Rx AMI_GetWave should be centered at -DC_Offset. Is that correct?

Q2. In statistical simulation, without AMI_GetWave, how does EDA tool knows 
where the center of the waveform at the slicer is?

One way to address Q2 is 1) keep the center of Rx AMI_GetWave output waveform 
at 0V (as in SerDes), and 2) make DC_Offset Usage InOut so that Rx AMI_Init can 
return the center of the waveform at the slicer to EDA tool.

Thanks,
Fangyi

-----Original Message-----
From: ibis-macro-bounce@xxxxxxxxxxxxx <ibis-macro-bounce@xxxxxxxxxxxxx> On 
Behalf Of Muranyi, Arpad
Sent: Tuesday, April 09, 2019 1:06 PM
To: 'IBIS-ATM' <ibis-macro@xxxxxxxxxxxxx>
Subject: [ibis-macro] New draft for BIRD197

[EXTERNAL]

Hello Everyone,

As you may recall, the vote for BIRD197.2 was postponed in the last IBIS Open 
Forum meeting with the request to the IBIS-ATM Task Group to fix the 
typographical errors which were discovered in it.

The attached file is a new draft for BIRD197.3 in which we corrected these 
problems.
I would like to ask everyone to review this document for the next IBIS-ATM 
meeting, and if we don't find any other problems, we will submit it to the Open 
Forum following that meeting.

Thanks,

Arpad
====================================================================

---------------------------------------------------------------------
IBIS Macro website  :  http://ibis.org/macromodel_wip/
IBIS Macro reflector:  //www.freelists.org/list/ibis-macro
To unsubscribe send an email:
  To: ibis-macro-request@xxxxxxxxxxxxx
  Subject: unsubscribe

Other related posts: