[ibis-macro] Quick questions on BIRD158.5

  • From: "Mirmak, Michael" <michael.mirmak@xxxxxxxxx>
  • To: "IBIS-ATM (ibis-macro@xxxxxxxxxxxxx)" <ibis-macro@xxxxxxxxxxxxx>
  • Date: Fri, 12 May 2017 01:18:24 +0000


Sorry for last-minute questions on BIRD158, but I wanted to ensure these could 
be addressed during the technical discussion in the Open Forum:


1)      The TX and RX "Analog Termination Circuit" sections - it's not 
immediately clear where in the specification these are supposed to go.  It 
would help to note the section in which these are to be inserted.

2)      In the text, the following phrase is used:


"Note that when the reserved parameter Ts4file is defined in the AMI model the 
Tx or the Rx schematic shown above is to be used in lieu of the analog buffer 
model and the package defined in the .ibs file. "


Will the phrase "and the package" regarding package models be revised or 
removed once BIRD189.x is approved?

3)      Related to this, the entire sentence should appear *before* the link 
setup circuit diagram that immediately precedes it, to prevent reader confusion.

4)      Also related to this, the link setup diagram should be altered to make 
the package portion of the "User Setup" block optional.  Otherwise, the diagram 
conflicts with the statement regarding the replacement of the package 
information in the .ibs file.

5)      The last paragraph of the BIRD text to be added to IBIS mentions step 
responses vs. impulse responses.  As the phrase "step response" is never used 
in IBIS 6.1, and the information supplied applies just as much to impulse 
responses, is the entirety of this paragraph needed?

Thank you!


-          MM