[ibis-macro] Re: Revised Backchannel BIRD

  • From: Walter Katz <wkatz@xxxxxxxxxx>
  • To: <ambrishv@xxxxxxxxxxx>, <ibis-macro@xxxxxxxxxxxxx>
  • Date: Thu, 3 Apr 2014 15:38:59 -0400 (EDT)

Ambrish,

 

I am really confused on how the parameter taps is used in the Statistical
and Time domain flow. In some places it is a coefficient between -1 and 1,
and some places it is an increment and decrement.  And some places there
seems to be an relationships of 1/32 between increments and coefficients.
Can you clarify this please.

 

Walter

 

From: ibis-macro-bounce@xxxxxxxxxxxxx
[mailto:ibis-macro-bounce@xxxxxxxxxxxxx] On Behalf Of Ambrish Varma
Sent: Wednesday, April 02, 2014 9:56 AM
To: ibis-macro@xxxxxxxxxxxxx
Subject: [ibis-macro] Revised Backchannel BIRD

 

Hi All,

The latest version of the Backchannel BIRD (draft 8) has been uploaded on
the ATM website and is available here:

http://www.vhdl.org/ibis/macromodel_wip/archive/20140401/ambrishvarma/Back
channel%20support%20BIRD%20147%20draft%208/Backchannel_BIRD147_Draft8.docx


Or

http://tinyurl.com/o8cqyqr

 

This is the version that was discussed at the 04/01/2014 ATM and includes
support for AMI_Init/Statistical Backchannel training.

 

Please let me know if there are any questions.

 

Thanks,

Ambrish.

 

Ambrish Varma.

Cadence Design Systems.

 

Other related posts: