[ibis-macro] Terminator Model_type and *input* Algorithmic Models?

  • From: "Mirmak, Michael" <michael.mirmak@xxxxxxxxx>
  • To: "IBIS-ATM (ibis-macro@xxxxxxxxxxxxx)" <ibis-macro@xxxxxxxxxxxxx>
  • Date: Sat, 5 Jan 2013 02:21:41 +0000

A simple question (I specialize in those): why are we prohibited from using 
Model_type Terminator and [Algorithmic Model] together?  The specification 
explicitly limits Terminator to input buffers, but that should only prevent 
using the Model_type with transmitters.  Wouldn't Terminator be a pretty 
friendly way of modeling receiver buffer analog impedances?  Nevertheless, 
Terminator is explicitly prohibited from use as a Model_type with [Algorithmic 
Model].



The parser (IBISCHK5, 5.1.2) correctly yields the following for such a 
combination:



ERROR - Algorithmic Model is not allowed for model modelname which is of type 
Terminator.



There's a related issue that there's no way to check whether I am combining a 
transmitter-only [Algorithmic Model] with an input or Terminator Model_type, 
but that's a separate problem.



Is it time for a BUG and a BIRD?



-        MM

Other related posts: