A question regarding usage type of jitter parameters came up in today's ATM. I checked the IBIS 5.1 spec and found that following reserved parameters Tx_DCD Tx_Jitter Rx_Clock_PDF Rx_Receiver_Sensitivity are allowed to have usage type of Info or Out. So their values can be returned by AMI_Init. Fangyi --------------------------------------------------------------------- IBIS Macro website : http://www.eda.org/pub/ibis/macromodel_wip/ IBIS Macro reflector: //www.freelists.org/list/ibis-macro To unsubscribe send an email: To: ibis-macro-request@xxxxxxxxxxxxx Subject: unsubscribe