[ibis-macro] Re: new BIRD for single-ended signal in AMI

  • From: "Fangyi Rao" <dmarc-noreply@xxxxxxxxxxxxx> (Redacted sender "fangyi_rao" for DMARC)
  • To: "ibis-macro@xxxxxxxxxxxxx" <ibis-macro@xxxxxxxxxxxxx>
  • Date: Tue, 16 Jul 2019 06:52:36 +0000

Based on Walter's suggestion I changed the Usage of DC_Offset from In to In or 
InOut. For Usage In, the output value of DC_Offset is assumed to be 0V 
according to the default value.

Fangyi

From: ibis-macro-bounce@xxxxxxxxxxxxx <ibis-macro-bounce@xxxxxxxxxxxxx> On 
Behalf Of Fangyi Rao
Sent: Sunday, July 14, 2019 12:40 PM
To: ibis-macro@xxxxxxxxxxxxx
Subject: [ibis-macro] new BIRD for single-ended signal in AMI


[EXTERNAL]
Hi All,

Per last week's ATM discussion I drafted the attached new BIRD titled "Enable 
Single-ended Signal in AMI Modeling". The basic idea is simple.


  1.  DC_Offset usage is InOut. Defaults for both input and output values are 0 
V.
  2.  Physical Rx input waveform = input waveform to Rx AMI_GetWave + input 
value of DC_Offset
  3.  Complete waveform at Rx output = output waveform of Rx AMI_GetWave + 
output value of DC_Offset returned by Rx AMI_Init
  4.  NRZ_Threshold is to be applied to the complete waveform at Rx output. 
Default is 0 V.

I'd like to introduce the BIRD at this week's ATM.

Regards,
Fangyi

Attachment: BIRD_enable_single_ended_signal_in_AMI.docx
Description: BIRD_enable_single_ended_signal_in_AMI.docx

Other related posts: