[ibis-macro] questions about Init input parameter string

  • From: <fangyi_rao@xxxxxxxxxxx>
  • To: <ibis-macro@xxxxxxxxxxxxx>
  • Date: Fri, 9 Jul 2010 22:26:04 -0600

Hi, AMI experts;

I have some questions about input parameter string of AMI Init.


1.       If a parameter is of Usage Info, shall it be included in the input 
parameter string to the Init call?

2.       If a parameter is of Usage Out, shall it be included in the input 
parameter string to the Init call?

3.       If a parameter is of Usage InOut, shall it be included in the input 
parameter string to the Init call?

4.       If a parameter is of Usage Info or Out, can its sub-parameter be of 
Usage In?

The current spec is not clear about what parameters go into the input string. 
We should clarify this in the clean-up BIRD.

Thanks in advance.

Fangyi

Other related posts: