[ibis-macro] Re: A question about IBIS-ISS

  • From: Walter Katz <wkatz@xxxxxxxxxx>
  • To: <Arpad_Muranyi@xxxxxxxxxx>, <ibis-macro@xxxxxxxxxxxxx>, "IBIS-users" <ibis-users@xxxxxxxxxxxxx>
  • Date: Thu, 2 Jul 2015 15:09:07 -0400 (EDT)

Arpad,

Given an interconnect subckt (a package model for example), how would the
model maker know what the initial condition is? This is not meant to be a
flippant answer, you do raise an interesting problem, particularly for
series blocking caps, and simulators that relay on starting off with a DC
solution.

Walter

-----Original Message-----
From: ibis-macro-bounce@xxxxxxxxxxxxx
[mailto:ibis-macro-bounce@xxxxxxxxxxxxx] On Behalf Of Muranyi, Arpad
Sent: Thursday, July 2, 2015 1:38 PM
To: ibis-macro@xxxxxxxxxxxxx; IBIS-users (ibis-users@xxxxxxxxxxxxx)
Subject: [ibis-macro] A question about IBIS-ISS

Hello Everyone,

I just noticed that the IBIS-ISS specification does not define/support the
initial conditions for capacitors and inductors. Does anyone remember why
these were omitted? It seems that these would be rather useful and
important features to have...

Thanks,

Arpad
========================================================================
---------------------------------------------------------------------