[ibis-macro] Re: BIRD 120.1 Question

  • From: "Muranyi, Arpad" <Arpad_Muranyi@xxxxxxxxxx>
  • To: "ibis-macro@xxxxxxxxxxxxx" <ibis-macro@xxxxxxxxxxxxx>
  • Date: Tue, 13 Mar 2012 15:39:41 +0000

Greg,

Section 2 is called APPLICATION SCENARIOS and section 3
is called  Reference Flows.  The first sentence in
section 2 says:

| The next two sections provide an overview of the two simulation types
| supported by the IBIS-AMI specification.

and the first sentence in section 3 says:

| The next two sections define a reference simulation flow for statistical
| and time domain system analysis simulations.

Does that answer your question?

Thanks,

Arpad
=========================================================

From: ibis-macro-bounce@xxxxxxxxxxxxx [mailto:ibis-macro-bounce@xxxxxxxxxxxxx] 
On Behalf Of Gregory R Edlund
Sent: Tuesday, March 13, 2012 8:36 AM
To: ibis-macro@xxxxxxxxxxxxx
Subject: [ibis-macro] BIRD 120.1 Question


Can anybody explain the difference between section 2.2 and 3.2 of BIRD 120.1?  
Both seem to be describing the high-level process for calculating a 
voltage-time waveform from AMI models, a channel, and a bit stream.

Thanks.

Greg Edlund
Senior Engineer
Signal Integrity and System Timing
IBM Systems & Technology Group
3605 Hwy. 52 N  Bldg 050-3
Rochester, MN 55901

Other related posts: