[ibis-macro] Re: TrainingDone for back-channel

  • From: <fangyi_rao@xxxxxxxxxxx>
  • To: <kwillis@xxxxxxxxxxx>
  • Date: Tue, 2 Aug 2011 11:21:38 -0600

Thanks, Ken. It looks fine.

Fangyi

From: Ken Willis [mailto:kwillis@xxxxxxxxxxx]
Sent: Tuesday, August 02, 2011 7:04 AM
To: RAO,FANGYI (A-USA,ex1)
Cc: ibis-macro@xxxxxxxxxxxxx
Subject: RE: TrainingDone for back-channel

Hi Fangyi,

I clarified the wording some more based on your feedback. How does this look?

TrainingDone is of usage InOut and is issued by the receiver model to signify 
the
completion of back-channel training. TrainingDone can also be initiated by the 
EDA
tool. In this case the parameter TrainingDone=True can be passed from the EDA 
tool
to the receiver model. Then the receiver model will re-issue the parameter
TrainingDone=True to the transmitter model to end the training process.

Thanks,

Ken Willis
Sigrity, Inc.
860-871-7070
kwillis@xxxxxxxxxxx<mailto:kwillis@xxxxxxxxxxx>

________________________________
From: fangyi_rao@xxxxxxxxxxx [mailto:fangyi_rao@xxxxxxxxxxx]
Sent: Monday, August 01, 2011 8:23 PM
To: kwillis@xxxxxxxxxxx
Cc: ibis-macro@xxxxxxxxxxxxx
Subject: RE: TrainingDone for back-channel

Hi, Ken;

I apologize for my late reply. The text looks fine. You may want to make it 
clear that EDA tool will pass the message issued by Rx with TrainingDone=True 
to Tx to end the training session.

Regards,
Fangyi


From: Ken Willis [mailto:kwillis@xxxxxxxxxxx]
Sent: Thursday, July 28, 2011 10:23 AM
To: RAO,FANGYI (A-USA,ex1)
Cc: ibis-macro@xxxxxxxxxxxxx
Subject: TrainingDone for back-channel

Hi Fangyi,

One input I got from the last conference call on back-channel was regarding the 
TrainingDone parameter from the standpoint of the EDA tool. Typically, the Rx 
will decide that training is completed and issue TrainingDone=True. The EDA 
tool should also be able to do this since this is an InOut parameter. The idea 
here is that the tool could pass TrainingDone=True to the Rx, and the Rx could 
re-issue it out to formally end the training process. So this would always end 
up going through the Rx for consistency. Here is what I would update in the 
BIRD:

TrainingDone:

TrainingDone is of usage InOut and is issued by the receiver model to signify 
the
completion of back-channel training. TrainingDone can also be initiated by the 
EDA
tool. In this case the parameter TrainingDone=True can be passed from the EDA 
tool
to the receiver model. Then the receiver model can re-issue TrainingDone=True to
end the training process.

Let me know if this would cover it.

Thanks,

Ken Willis
Sigrity, Inc.
860-871-7070
kwillis@xxxxxxxxxxx<mailto:kwillis@xxxxxxxxxxx>


Other related posts: