[ibis-macro] Re: input to Tx analog model

  • From: "Walter Katz" <wkatz@xxxxxxxxxx>
  • To: <Arpad_Muranyi@xxxxxxxxxx>, <ibis-macro@xxxxxxxxxxxxx>
  • Date: Fri, 21 Jan 2011 10:46:09 -0500 (EST)

Arpad,



You can connect the output of Tx AMI_GetWave on the High (Positive side of
the network and 0 on the Low (Negative side) or ½ of Tx AMI_GetWave on the
High (Positive side of the network and -½ of Tx AMI_GetWave on the Low
(Negative side). At the Rx analog output one uses the differential output.
All in between is LTI so the answer is the same. AMI does not currently
support common mode affects.



Tuesday will be the last meeting of IBIS-ATM. I would suggest that we
spend a little time on a summary that you would give at the Summit.
Secondly, I would like a little time (~15 minutes) to go over BIRD-123,
the Dependency BIRD.



Walter



From: ibis-macro-bounce@xxxxxxxxxxxxx
[mailto:ibis-macro-bounce@xxxxxxxxxxxxx] On Behalf Of Muranyi, Arpad
Sent: Thursday, January 20, 2011 7:54 PM
To: ibis-macro@xxxxxxxxxxxxx
Subject: [ibis-macro] Re: input to Tx analog model



I got stuck in my thinking on one detail question:



If the Tx GetWave output is a difference waveform but

the analog Tx model has a differential in/out (4-port),

how do we convert the difference waveform coming from

Tx GetWave into a differential waveform for the Tx

analog model?



Since the input to Tx GetWave is +/- 0.5 volt, centered

around 0, it would be tempting to say, let?s just make

a copy of the Tx GetWave output, multiplied by -1.  But

this only works if the difference waveform from Tx GetWave

is guaranteed to be DC free.  I am not sure if that is a

safe assumption.



Does anyone have any suggestions?



Arpad

===========================================================



From: fangyi_rao@xxxxxxxxxxx [mailto:fangyi_rao@xxxxxxxxxxx]
Sent: Thursday, January 20, 2011 4:33 PM
To: Muranyi, Arpad; ibis-macro@xxxxxxxxxxxxx
Subject: RE: [ibis-macro] Re: input to Tx analog model



Arpad;



Yes, we are asking the same questions. While yours are more focusing on
AMI simulation, mine are focusing on general SPICE transient simulation. A
subtitle difference is that in AMI it?s the EDA tool that internally
create the input to Tx analog models but in transient user has to create
the input explicitly on the schematic. So these questions are more
prominent in transient simulations.



Regards,

Fangyi



From: ibis-macro-bounce@xxxxxxxxxxxxx
[mailto:ibis-macro-bounce@xxxxxxxxxxxxx] On Behalf Of Muranyi, Arpad
Sent: Thursday, January 20, 2011 2:16 PM
To: ibis-macro@xxxxxxxxxxxxx
Subject: [ibis-macro] Re: input to Tx analog model



Fangyi,



You are basically asking the same question to which I was

trying to find the answer in the last few ATM meetings and

email discussions on the topic of the AMI analog models.

The difference you describe is exactly why I am now asking

the questions ?what is ***the*** analog model? or AMI?  Is

the stimulus PWL source included or not?  Do we need two

different types of models?  Do we need to describe the

different usages and/or flows?  I still do not see the end

of the tunnel in this discussion.



I thought when Walter posted his HSPICE netlist

http://www.vhdl.org/pub/ibis/macromodel_wip/archive/20101214/walterkatz/BI
RD%20122%20Sample%20SPICE%20Deck/generic_tstonefile_spice.pdf

that we had the answer.  But when Walter brought up the

possibility of using the output of Tx GetWave as the input

to the Tx analog model, I lost that feeling.  I am still

looking for answers and suggestions on how to write the

specification in an unambiguous way to describe the analog

models.



I am open to any suggestions?



Thanks,



Arpad

============================================================



From: ibis-macro-bounce@xxxxxxxxxxxxx
[mailto:ibis-macro-bounce@xxxxxxxxxxxxx] On Behalf Of
fangyi_rao@xxxxxxxxxxx
Sent: Wednesday, January 19, 2011 9:11 PM
To: ibis-macro@xxxxxxxxxxxxx
Subject: [ibis-macro] input to Tx analog model



Hi, Experts,



In light of IBIS analog model enhancement discussed at recent ATM
meetings, I want to raise a question: in SPICE level transient simulations
(w/o AMI), what is the input signal to the Tx analog model?



In IBIS 5.0 the answer is simple. The input is digital signal whose
threshold crossing events trigger rise and fall edges being formed and
transmitted. The swing and waveform of the edges are part of the analog
model. They are independent of the input signal and user doesn?t need to
know about them.



If we are to make Tx analog model able to accept AMI_GetWave output
waveform as input, we need to abandon this notion of event trigger and
make the input signal a continuous analog waveform (e.g. PWL). The output
waveform of Tx analog model will be directly shaped by the input waveform.
As a result, to run a SPICE level transient simulation (w/o AMI) user has
to look up the swing and slope parameters (Voh, Vol, trise, etc) from
model files in order to create the input signal with proper amplitude and
shape.



Is this an acceptable use model for transient? If user replace his old
model with a new one, then the result is most likely wrong because his old
digital input signal doesn?t have the correct amplitude and slope.



Regards,

Fangyi

Other related posts: