Bob, I got it now... Here is BIRD 160.1_draft2 with that corrected. Thanks, Arpad ============================================ -----Original Message----- From: Bob Ross [mailto:bob@xxxxxxxxxxxxx] Sent: Thursday, April 11, 2013 5:37 PM To: Muranyi, Arpad; 'IBIS-ATM' Subject: RE: [ibis-macro] Re: BIRD160 - parameters comments Arpad: In the first part of BIRD160.1 - the table and hierarchy diagram (formatting is lost here). Table 11 - Language Extension Keywords Keyword Description [External Circuit] [End External Circuit] References enhanced descriptions of structures on the die, including digital and/or analog, active and/or passive circuits [External Model] [End External Model] Same as [External Circuit], except limited to the connection format and usage of the [Model] keyword, with one additional feature added: support for true differential buffers [Node Declarations] [End Node Declarations] Lists on-die connection points related to the [Circuit Call] keyword [Circuit Call] [End Circuit Call] Instantiates [External Circuit]s and connects them to each other and/or die pads [Converter Parameters] [End Converter Parameters] Adds tree-structured parameters named within a .ibs file The placement of these keywords within the hierarchy of IBIS is shown below: +-- [Component] │ │ │ +-- [Node Declarations] │ │ L-- [End Node Declarations] │ │ │ +-- [Circuit Call] │ │ L-- [End Circuit Call] │ │ │ +-- [Model] │ │ │ +-- [External Model] │ │ L-- [End External Model] │ +-- [External Circuit] │ L-- [End External Circuit] │ +-- [Converter Parameters] │ L-- [End Converter Parameters] Bob -----Original Message----- From: ibis-macro-bounce@xxxxxxxxxxxxx [mailto:ibis-macro-bounce@xxxxxxxxxxxxx] On Behalf Of Muranyi, Arpad Sent: Thursday, April 11, 2013 3:27 PM To: 'IBIS-ATM' Subject: [ibis-macro] Re: BIRD160 - parameters comments Bob, I am not sure what you mean by this. I just checked BIRD 160.1 and it correctly uses [Begin / End Parameter Trees] in the ANY OTHER BACKGROUND INFORMATION section and in the example at the end. Where did you use [Begin / End Converter Parameters] instead? Thanks, Arpad ================================================================= -----Original Message----- From: Bob Ross [mailto:bob@xxxxxxxxxxxxx] Sent: Thursday, April 11, 2013 2:55 PM To: Muranyi, Arpad; 'IBIS-ATM' Subject: RE: [ibis-macro] Re: BIRD160 - parameters comments Arpad: I just noticed my mistake based on BIRD153.1. The [Converter Parameters]/[End Converter Parameters] should be [Begin Parameter Trees]/[End Parameter Trees]. I think the details of BIRD153.1 needs to be decided before we vote on BIRD160 and BIRD153.1. Bob --------------------------------------------------------------------- IBIS Macro website : http://www.eda.org/pub/ibis/macromodel_wip/ IBIS Macro reflector: //www.freelists.org/list/ibis-macro To unsubscribe send an email: To: ibis-macro-request@xxxxxxxxxxxxx Subject: unsubscribe
Attachment:
BIRD160_1_draft2.docx
Description: BIRD160_1_draft2.docx