Scott-
Excellent answer. Thanks for the information.
Mike S.
On 05/27/2010 06:25 PM, Scott McMorrow wrote:
I
also
wonder what you mean by "large errors". What is your numerical
estimate of the magnitude of such errors? How did you perform that
estimate? What data did you base your estimate on?
Mike S.
Numerical error estimate - approximately 9 to 10%, depending on
compensation inductance
- Lumping the receiver at the termination introduces about an
additional 9% loss in eye height, along with pulse distortion.
Estimate performed using HSPICE transient simulation of receiver circuit
Published data on device input characteristics correlated to
measurements
--
Scott McMorrow
Teraspeed Consulting Group LLC
121 North River Drive
Narragansett, RI 02882
(401) 284-1827 Business
(401) 284-1840 Fax
http://www.teraspeed.com
Teraspeed® is the registered service mark of
Teraspeed Consulting Group LLC
|